SPECIFICATIONS (Nominal):
The Autocorr� Plus, the fourth in the Clarity� Series is a cost-effective, versatile pulse oximeter. A high-resolution electroluminescent screen display provides two user configurable traces. An optional recorder (BCI, Inc. catalog #3408) provides for high-resolution graphics printing. Use as a stand-alone device, or combine with any of the other Clarity� Systems for multi-parameter monitoring.
Displays:
Display Electroluminescent
Resolution 160 x 80 pixels
Waveforms ECG, Plethysmogram
Graphic Trends SpO2, Pulse Rate (Heart Rate), Pulse
Signal Strength & Respiration
SpO2 3-digit (LED display)
0.56 inches (14.2 mm) high
Pulse Rate/ 3-digit (LED display)
Heart Rate (ECG) 0.43 inches (10.9 mm) high
Pulse Strength Logarithmically scaled 10-segment
LED bar graph
Respiration 3-digit 10 x 14 pixel font (EL Panel)
Indicators:
Low Battery LOW BATTERY message when
10 minutes of battery life remain
Audio Disabled SILENCED BELL icon indicates temporary or Indefinite status
Asystole Alarm ALARM LED will flash, ASYSTOLE message on screen flashes
SpO2 Sensor Message indicates sensor problem
SpO2 Search Message indicates monitor is searching for a pulse
Artifact Message indicates presence of excess motion or other artifact
ECG/Lead Fail Message indicates a lead disconnect condition
Charge Green LED indicates external power and battery is charging
Pace Detect A line appears on screen when pacemaker signal is detected
SpO2:
Range 0-100%
Accuracy �2% @ 70-100% �3% @ 50-69%
Alarm Range High: 50-100% & Off (1% steps)
Low: 50-100% & Off (1% steps)
Averaging 8, 16 pulse beat average
Pulse Rate (SpO2) or Heart Rate (ECG)
Range 30-254 bpm
Accuracy > of �2% or �2 bpm
Alarm Range High: 30-254 bpm & OFF (1 bpm steps)
Low: 30-254 bpm & OFF (1 bpm steps)
Averaging 8 or 16 second average
ECG:
Configuration 3- or 5-lead
Lead Selection I, II, III, aVR, aVL, aVF and V
Gain X1, X2, X4, X8
Pace Detect Yes
Pace Reject Yes
Sweep Speed 12.5 or 25 mm/sec
Respiration:
Measuring Method Impedance Pneumography
Rate 5 to 150 breaths/min
Accuracy > of �2% or �2 breaths/min over full range
Dimensions: 3.5" H x 10.0" W x 5.5" D
88.9mm H x 254mm W x 139.7 mm D
Weight:
5 pounds (2.27 kg)
AC Charger Power Requirements:
Wall Mount 105-125V ~, 60 Hz
100V ~, 50 Hz (optional)
Table Top 230V ~, 50/60 Hz
Battery Life:
Standard Lead - Acid battery:
Internal rechargeable; not user replaceable
Approximately 45 minutes continuous use
Fully charges in 6 hours
Printer Output:
Serial/Analog RS232C serial output of data
Optional digital (remote alarm) interface
Printer (Optional):
Catalog #3408 Printer provides data log (Interval) trends & waveform printouts
Environmental Specifications:
Operating Temperature 0� - 55� C
Storage Temperature -40� - 75� C (-40� - 167� F)
Relative Humidity 10-95% (storage)
(non-condensing) 15-95% (operating)
Safety Standards:
Safety EN60601-1, EN60601-1-1, UL 544,
CSA Std. C22.2 No. 125-1984
EMC EN60601-1-2